A 40-year-old mason worker reported to our clinic with a history of injury to the left eye while hammering a nail about one month ago. On examination, the visual acuity was 20/20. There was no conjunctival congestion or anterior chamber reaction. A linear corneal penetrating wound, self-sealed (Seidel’s negative), was present. There was an irregular foreign body embedded in the lens [Figure 1a and b]. The posterior capsule appeared uninjured. The retinal evaluation by indirect ophthalmoscope was unremarkable. A computed tomography scan showed a well-defined hyperdense foreign body in the lens, suggesting its metallic nature. The patient was hailing from far and wanted surgical removal to avoid follow-up visits. Hence, we planned phacoemulsification of the lens and foreign body extraction with vitrectomy backup in place in anticipation of any posterior capsular weakness. Intraoperatively, after trypan blue staining, an anterior capsular tear was evident, which was included in the capsulorhexis [Figure 1c]. After nuclear matter removal using phacoemulsification, viscoelastic was used to maneuver the foreign body to the entry wound and McPherson forceps were used for its extraction [Figure 1d]. The CT scan image of the foreign body has been provided for reference in Figure 2. Subsequently, a hydrophobic intraocular lens was implanted in the bag [Figure 3]. Postoperatively, the patient had visual acuity of 20/20 on post-operative day one. Topical steroids were given to prevent any post-operative inflammation.
Intralenticular foreign bodies (ILFB) constitute 5–10% of all intraocular foreign bodies (IOFBs).[1] The metallic ILFB’s may remain inert for long periods or be complicated by cataract, uveitis, glaucoma, and siderosis bulbi.[2] If damage to the lens is localized, the visual axis is uninvolved, and the nature of the foreign body is nonmagnetic and inert, we can observe, and the foreign body may be left in situ. There are reports of focal lens opacities caused by minute, embedded foreign bodies where patients can maintain good visual function. If the foreign body is medium or large in size and metallic in nature, it warrants removal as the risk of complication is higher.[3]
Arora et al. have suggested the use of McPherson forceps (intraocular lens holding forceps) as an efficient alternative to a magnet for the removal of metallic foreign bodies.[4]
Ethical approval
The Institutional Review Board approval is not required.
Declaration of patient consent
The authors certify that they have obtained all appropriate patient consent.
Conflicts of interest
There are no conflicts of interest.
Use of artificial intelligence (AI)-assisted technology for manuscript preparation
The authors confirm that there was no use of artificial intelligence (AI)-assisted technology for assisting in the writing or editing of the manuscript and no images were manipulated using AI.
Financial support and sponsorship
Nil.
References
- Management of intraocular foreign bodies. Ophthalmology. 1987;94:1647-53.
- [CrossRef] [PubMed] [Google Scholar]
- Intralenticular metallic foreign body. Aust N Z J Ophthalmol. 1996;24:361-3.
- [CrossRef] [PubMed] [Google Scholar]
- Lens preservation after intraocular foreign body injuries. Ophthalmology. 1996;103:1563-7.
- [CrossRef] [PubMed] [Google Scholar]
- Intralenticular foreign bodies: Report of eight cases and review of management. Indian J Ophthalmol. 2000;48:119-22.
- [Google Scholar]